Design method of small scaled shaking table test structural model lacking artificial mass

ZHAO Zuozhou,GUAN Hua,QIAN Jiaru
DOI: https://doi.org/10.14006/j.jzjgxb.2010.07.010
2010-01-01
Abstract:Shaking table test is an important method to study dynamic performance of a structure under earthquake.With a bay 6-story prototype RC frame structure as an example,this paper presents design results of two series scaled models designed following the general similitude laws.One series scaled models were designed with element reinforcement ratio being constant while the other series models were designed following the similarity relation of element load carrying capacity.Pushover analysis and nonlinear dynamic analysis of these models under different artificial mass degrees were carried out by using software SAP2000 and MSC.MARC respectively.The analytical results indicate that if mechanical parameters of the model concrete satisfies the similitude requirement but mechanical properties of the model reinforcement are close to those of the prototype reinforcement,the seismic resisting capacity of the frame predicted based on the scaled model designed following element reinforcement ratio being constant can be significantly overestimated.While those following the similarity relation of element load carrying capacity work well.If the element's reinforcement ratio is high,influence of the lacking artificial mass degree on model response is not obvious.A new method on adjusting element reinforcement ratio based on Young 's modulus ratio of model reinforcement bar is proposed.
What problem does this paper attempt to address?