Numerical simulation of non-destructive test of surface crack of straight seam welding pipe by electromagnetically stimulated thermography

Li Longbo,Li Guohua,Gao Juchun,Lin Xiaofeng,Xie Liming
DOI: https://doi.org/10.13251/j.issn.0254-6051.2013.09.030
2013-01-01
Abstract:Non-destructive test of surface crack of straight seam welding pipe is stimulated by ANSYS software. Influence of electromagnetic excited frequency,intensity of excited current,coil lift-off height and crack size on the crack detection of thermal infrared imager were researched. The results show that with electromagnetic exitation frequency and current density increasing,the maximum temperature and the optimal detection period increase. There is no detectable time period when frequency is 1 kHz. The crack dectectability decreases with coil life-off height increasing. The maximum temperature difference and the optimal detection period increase and decrease respectively with crack length and depth increasing. The change of crack width has little impact on detection. The accuracy of simulation results are still needed to be tested by practice.
What problem does this paper attempt to address?