Simulation and Analysis on Performance of Parallel Flow Type Condenser of Automotive Air Conditioner

ZHANG Kai,WANG Dong,YANG Zhigang,CHEN Hui
DOI: https://doi.org/10.3969/j.issn.1006-0871.2011.03.013
2011-01-01
Abstract:To analyze flow and heat transfer performance of parallel flow type condenser of automotive air conditioner,refrigerant flow is supposed to be 1D type along tube direction,air flow is treated as zero dimension type,the refrigerant pressure drop due to acceleration is ignored,and the homogenous phase model is used in the two phase flow of refrigerant.A parallel flow type condenser model is built by AMESim,and the accuracy of the model is verified by comparing with experimental results.The structural parameters of the condenser are changed to simulate and analyze its performance.The result is that the performance could be improved with reasonable refrigerant circuit configuration.With the increase of refrigerant circuit number,heat transfer rate increases,however,the pressure drop increases too.When the total cross sectional area of refrigerant side is constant,heat transfer rate increases with the increase of micro channel number.When the air velocity is slow,heat transfer rate increases with the decrease of fin pitch.
What problem does this paper attempt to address?