The simulation analysis and comparison of R404A and R410A in parallel-flow type condenser

Kan Jie,Hao Liang,Li Tao,Li Qiang,Yuan Xiuling,Dong Xiaojun
DOI: https://doi.org/10.3969/j.issn.1009-8402.2007.01.013
2007-01-01
Abstract:Derives the mathematic model of distributed parameter for parallel-flow type condenser.Carries out the simulation and analysis of the heat transfer and the flow characteristics using the refrigerant R134a,the new refrigerant mixture R404A and R410A in parallel-flow type condenser.Compares the heat transfer and flow parameters(heat transfer coefficient and the pressure drop etc.) for these three refrigerants under both the same and different operating conditions.The results show that under the operating conditions for the automobile air-conditioning,R410A and R404A have better flow and heat transfer performances than R134a.R410 is even better than R404A in the heat transfer and flow performances,so as the new refrigerant mixtures using in the middle and low temperatures,R410A is more suitable for using in the parallel-flow type condenser.
What problem does this paper attempt to address?