A Research on the Wet Performance of New Parallel Flow Evaporator for Automotive Air Conditioners

Shi Junye,Qu Xiaohua,Qi Zhaogang,Chen Jiangping
DOI: https://doi.org/10.19562/j.chinasae.qcgc.2011.01.018
2011-01-01
Abstract:An experimental study is carried out on the wet performance of new parallel flow evaporator for automotive air conditioners,which is then compared with baseline laminated evaporator.Dynamic dip test results show that parallel flow evaporator has better condensate drainage performance.The results of enthalpy difference test reveal that,under different working conditions,compared with laminated evaporator,the parallel flow evaporator has slightly higher cooling capacity(up to 3.3% difference),higher air side pressure drop,21.3%~29% higher over all heat transfer coefficient and slightly higher dehumidify rate.The results of all tests indicate that the new parallel flow evaporator has excellent performance and can by all means replace laminated evaporator.