Flat tube structure on refrigerant-side performance of parallel flow type condenser

Zhaohui SHU,Conglai LI,Huanxin CHEN,Tingxiang JIN,Yan LUO,Weihong FU,Fubao WANG
DOI: https://doi.org/10.3321/j.issn:0438-1157.2008.z2.023
2008-01-01
Abstract:Parallel flow condenser is a new type of higher and compact heat exchanger,its application in domestic air conditioner still has some problems to be unsolved.Yang & Webb's recommended correlations of heat transfer and friction coefficients were employed in this paper to simulate and study the influence of flat tube structure on heat transfer and pressure drop performance.The result shows that reducing the number of flat tube inner hole,inner hole width,inner hole height,or the aspect ratio will raise the refrigerant-side heat transfer coefficient and pressure drop.The result provides a theoretical basis for selection of flow parallel flat tube parameters for the domestic air conditioner condenser.
What problem does this paper attempt to address?