Catalytic Membrane Reactors for Partial Oxidation Using Perovskite Hollow Fiber Membranes and for Partial Hydrogenation Using a Catalytic Membrane Contactor
Jurgen Caro,Karl J. Caspary,Christof Hamel,Born Hoting,Peter Koelsch,Bernd Langanke,Konrad Nassauer,Thomas Schiestel,Andrea Schmidt,Reinhard Schomaecker,Andreas Seidel-Morgenstern,Evangelos Tsotsas,Ingolf Voigt,Haihui Wang,Rafael Warsitz,Steffen Werth,Aurel Wolf
DOI: https://doi.org/10.1021/ie0609620
2006-01-01
Industrial & Engineering Chemistry Research
Abstract:Two consecutive model reactions of the type A -> B -> C are studied in two kinds of catalytic membrane reactors. The partial oxidation of methane to synthesis gas due to CH4 + (1)/O-2(2) -> CO + 2H(2) was investigated in a novel type of permselective membrane reactor using perovskite hollow fibers for the selective separation of oxygen from air. Partial hydrogenations were studied in a pore-through-flow membrane reactor as a special type of a catalytic membrane contactor. The catalytically functionalized pores of the membrane provide a medium with defined contact times for the cofeed of hydrogen and an unsaturated hydrocarbon, and the attempts of the scale-up of the successful laboratory experiments to the pilot scale are reported.