Corrosion Behavior of Ti–5Ag Alloy with and Without Thermal Oxidation in Artificial Saliva Solution

B. B. Zhang,B. L. Wang,L. Li,Y. F. Zheng
DOI: https://doi.org/10.1016/j.dental.2010.10.005
IF: 5.687
2010-01-01
Dental Materials
Abstract:Objectives. The aim of the present study was to investigate the effect of thermal oxidation on the corrosion behavior of Ti-5Ag alloy.Methods. The microstructure of Ti-5Ag alloy without and with thermal oxidization treatment were characterized, with commercial pure (CP) Ti as control, by means of X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). The electrochemical behavior in artificial saliva solution was compared for CP Ti, Ti-5Ag alloy with and without thermal oxidation.Results. Compared to CP Ti, Ti-5Ag alloy without thermal oxidization treatment possessed much lower current density, higher open circuit potential, larger impedance value, and its corrosion resistance could be further improved with thermal oxidation.Significance. The corrosion resistance was enhanced by Ag addition for titanium and could be further improved by thermal oxidation. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.