Operation Effect of Upgraded Carrousel Oxidation Ditch System

Qin-ding LI,Xian-zhong MAO,Qiao-yu CHEN
DOI: https://doi.org/10.3969/j.issn.1000-4602.2012.19.025
2012-01-01
Abstract:The operation effect of the upgraded Carrousel oxidation ditch system of Qilidian WWTP in Guilin was investigated.The results showed that the removal rates of NH+4-N and TP in the upgraded Carrousel oxidation ditch system were up to 60% and 80% respectively,and that the effluent quality met the first level B criteria specified in the Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant(GB 18918-2002).The influent quantity in summer was about 40% higher than in winter.In summer,the pollutant loading was lower and the removal rate of NH+4-N was above 20% higher than in winter.There was no difference in removal of other pollutants in summer and winter.Biological function zones,such as anoxic zone,anaerobic zone and aerobic zone,were present in the ditch.Flow rate,temperature and DO had great influence on the wastewater quality distribution in the ditch.The measured removal rate of NH+4-N in October was 25.6% higher than in April.Nitrate inhibited phosphorus release in the ditch,and the phosphorus release rate in April was 1.5 times of that in October.