Abstract:To enhance nitrogen removal, a systemic monitoring of the biological and hydrological parameters of Carrousel oxidation ditch in Changsha second wastewater treatment plant was carried out to study the feasibility of simultaneous nitrification and denitrification (SND). The variation and distribution of parameters such as flow velocity, the concentration of dissolved oxygen(DO) and mixed liquor suspended solids (MLSS) in oxidation ditch were measured and analysed, which were major control factors for SND. The dimensional distribution of flow velocity, DO and MLSS were affected markedly by the open condition of the fans, DO along the ditch changed obviously with time. DO and flow velocity were higher and the mixing of MLSS was sufficient when five fans were opened, while there was lower flow velocity (<0.15m/s) in middle ditch when three fans were opened. The feasible operation conditions for SND were lower dissolved oxygen concentration, lower flow velocity and higher concentration of MLSS.
What problem does this paper attempt to address?