Experiments on the mechanical properties and the welded seam properties of architectural membranes

CHEN Wu-jun,TANG Ya-fang,ZHAO Da-peng,REN Xiao-qiang,FU Gong-yi,DONG Shi-lin
DOI: https://doi.org/10.3969/j.issn.1006-6578.2007.01.007
2007-01-01
Abstract:A series of experiments have been carried out in this paper for some commonly used architectural membranes.The uni-tension of ETFE and PTFE are first tested.The stress-strain curves,the broken style,the ultimate strength and the broken elongation ratio,are thus obtained for the corresponding membrane.The characteristics of the membrane subjected to the cyclic loading are tested to determine the elastic modulus(elastic stiffness) from the cycling stress-strain curve of ETFE and PTFE.The reasonable widths of backup strip are experimented with the strength factor of the welded seam for a particular kind of PVC/PES.Finally,the various lapped widths of the welded seam are experimented for FiberTop T400 PTFE membrane,and the related strength factor are obtained for comparison.The presented works are valuable to the design of the practical membrane structures.
What problem does this paper attempt to address?