Investigation and Development of Operational Amplifier of High-voltage Stimulus for Measuring the Hysteresis Loop of Ferroelectric Thin Films

LI Shao-kang,WU Xiao-qing,LIN Peng
DOI: https://doi.org/10.3969/j.issn.1673-9965.2006.01.002
2006-01-01
Abstract:The coercive field of some kind of ferroelectric thin films is very high,and a stronger stimulus is needed for measuring their hysteresis loop.The theory of original measuring system and a new operational amplifier of high-voltage stimulus system have been analyses and developed in the presat work.The continuous output voltage and current can be up to ±100V and 10mA during 0.1Hz~10KHz,respectively.In order to provide the higher voltage amplitude of stimulus,it has been carefully designed and developed.The amplifier meets the prospective target by adopting a few effective methods,such as voltage and current limits at input port and transient voltage suppressing at output port.It has been employed in measuring PZT thin film of 2.8μm thickness by combining the original measuring system and the results,namely hysteresis loop and I-V curve,are presented.
What problem does this paper attempt to address?