TOP JOINT STUDY ON TEMPERATURE STRESS FOR SUPER-LONG SLAB-COLUMN STRUCTURE

Minghai Dong,Li Song,Ying Shao
DOI: https://doi.org/10.1142/s0217979208050942
2008-01-01
International Journal of Modern Physics B
Abstract:In this paper, top joint method is proposed to solve a practical engineering problem of temperature stress and temperature crack of super-long slab-column structure bearing temperature difference. From the study, it is shown that as for super-long slab-column structure undergoing temperature difference of inside and outside, joint located in bottom stories nearly has no influence on temperature stress and deformation while joint in top stories can significantly reduce temperature stress and deformation of super-long slab-column structures. In addition, comparison of joints located in top one story, top several stories and from bottom to top stories indicates that influences of them on temperature stress and deformation are similar. As for top joint method, among which cantilever plate method, double column method and corbel method are discussed and results indicate that influence effects of these methods on structures are similar.
What problem does this paper attempt to address?