New refrigeration system using CO2 vapor-solid as refrigerant

Dongping Huang,Guoliang Ding,Hans Quack
DOI: https://doi.org/10.1007/s11708-008-0070-x
2008-01-01
Frontiers of Energy and Power Engineering in China
Abstract:A refrigerant must be in the vapor-liquid phase in a vapor-compression refrigeration system, therefore, CO2 cannot be used as a refrigerant for temperatures lower than 256uC because solid CO2 will form under the triple point temperature of 256uC. A refrigeration system with CO2 vapor-solid particles as refrigerant is put forward, by which a temperature lower than the triple point is achieved. An adjustable nozzle, a sublimator, a high-pressure regulating valve and a low-pressure regulat- ing valve are used to replace the conventional evaporator. Theoretical cycle analysis of the refrigeration system shows that its COP can be 50% higher than that of the conventional one.