Experimental Study on an Absorption Refrigeration System at Low Temperatures

Yijian He,Guangming Chen
DOI: https://doi.org/10.1016/j.ijthermalsci.2006.06.002
IF: 4.779
2007-01-01
International Journal of Thermal Sciences
Abstract:The heat-driven auto-cascade absorption refrigeration cycle can be used at low temperatures, and a novel auto-cascade absorption refrigeration system is proposed to gain better performances with a refrigerating temperature as low as -50 degrees C. The new system uses a mixture of R23 + R32 + R134a/DMF as its working pair and its characteristic study is carried out under different operational conditions. It has successfully obtained a refrigerating temperature of -47.2 degrees C under the generating temperature of 163 degrees C. This refrigerating temperature is far lower than that of a traditional absorption refrigeration system with the same working pair, and it is also lower than that of an auto-cascade absorption refrigeration system using R32 + R134a/DMF as its working pair. From the experimental results, it is clearly seen that this new system shows.a rapider lowering rate of refrigerating temperature than that of an auto-cascade absorption refrigeration system using R23 + R134a/DMF as its working pair. The results of experimental analyses imply that this new absorption refrigeration system can be used in the deep-freezing as low as -50 degrees C by utilizing low-potential thermal power. Its potential of industrial application might be greater than that of an auto-cascade absorption refrigeration system using R23 + R134a/DMF as its working pair in the future. (c) 2006 Elsevier Masson SAS. All rights reserved.
What problem does this paper attempt to address?