A NOVEL COMBINED EJECTOR-ABSORPTION REFRIGERATION CYCLE

Daliang Hong,Liming Tang,Yunxia Zou,Yijian He,Guangming Chen
DOI: https://doi.org/10.19912/j.0254-0096.2011.12.016
2011-01-01
Abstract:To make refrigeration at low temperature with low-grade heat source, a novel combined ejector-absorption refrigeration cycle was proposed in this paper. In the new cycle, part of saturated liquid refrigerant from the condenser was pumped to saturated pressure of the refrigerant at generation temperature. This stream was heated into saturated vapor in a boiler and injected the superheating refrigerant vapor from a preheater to condenser pressure. Since the generation pressure is lower than condenser pressure in the new cycle, the system can make refrigeration at low temperature with low-grade heat source. The research results show that the generation temperature of the new cycle is even lower than that of the conventional two-stage absorption refrigeration cycle to make refrigeration at the same low temperature. In addition, the COP of the new cycle is much higher than that of single-effect cycle at the low refrigeration temperature and generation temperature. If the refrigeration temperature or the temperature of heat source is high enough, the COP of the new cycle is the same as that of the conventional single-effect cycle.