Experimental Research on the Performance of the Diffusion Absorption Refrigerator with Mixed Fluoride Refrigerants

S. K. Wang,J. Wang,Q. Wang,Y. L. Wang,J. Y. Zhao,G. M. Chen
DOI: https://doi.org/10.1016/j.ijrefrig.2017.05.027
IF: 4.14
2017-01-01
International Journal of Refrigeration
Abstract:A diffusion absorption refrigerator (DAR) operating with mixed fluoride refrigerants was built to obtain low refrigerating temperature at low generating temperature. Two groups of mixed fluoride refrigerants, R23/R134a and R23/R32/R134a, were tested experimentally. The N, N-dimethylformamide (DMF) and helium were used as the absorbent and inert gas, respectively. For the DAR with R23/R134a, the refrigerating temperature was not obviously influenced by the concentration of R23 in the mixed refrigerant vapor or the amounts of helium. For the DAR with R23/R32/R134a, an optimal concentration of R32 in the mixed refrigerant vapor and an optimal pressure were both found to achieve the lowest refrigerating temperature which was -28.8 degrees C at a generating temperature of 106.9 degrees C, and a refrigerating temperature of -23.7 degrees C was obtained at an extraordinarily low generating temperature of 83.3 degrees C. It showed the promising potentials of DAR operating with mixed fluoride refrigerants in applications of low temperature refrigeration and efficient utilization of the low-grade thermal energy. (C) 2017 Elsevier Ltd and IIR. All rights reserved.