Heat exchange network retrofit of an aromatics extraction process

SUN YanZe,FENG Xiao
2006-01-01
Abstract:The pinch analysis is used to investigate the energy features of the heat exchane network of an aromatics extraction process. Based on the pinch analysis principles,the unreasonable matches are found,which give an energy-saving potential of 17. 11% and 19. 08% for the heating and cooling utilities,respectively. According to the pinch analysis principle totally,a retrofit scheme is proposed with minimum utilities, which needs more capital cost. Then other scheme is proposed by considering the present network structure and mainly following the pinch analysis principles,which can save heating and cooling utilities by 13.32% and 10.26% , respectively and has lower capital cost. The payback period for both schemes is short.