HPLC Method for the Determination of Sirolimus in Human Plasma

SUN Yi-xin,YU Zi-cheng,LIAO Qing-chuan,XU Kang-kang
DOI: https://doi.org/10.3969/j.issn.1673-7806.2010.06.025
2010-01-01
Abstract:Objective: To establish a rapid and feasible high-performance liquid chromatographic(HPLC) method for the determination of Sirolimus(SRL) in human plasma.Methods: Prior to analysis,SRL was isolated from plasma sample using ultra filtration.The extracts were injected onto an Zorbax Eclipse XDB C18(4.6 mm×150 mm,5 μm) column at 50℃ with detection UV wavelengths set at 278 nm.The mobile phase was consisted of Meth-ACN-H2O(50∶22∶28,v/v),at a flow rate of 1.2 mL·min-1.Result: Calibration curves were linear over a concentration range of 2.5~50.0 μg·mL-1 for SRL.The average recoveries of SRL were 103.2%.The within-day precision and between-day precision of SRL were less than 5% and 4%.Conclusion: This method is simple,quick and accurate and can be used for routine monitoring and clinical study of SRL pharmacokinetics.