Determination of Formaldehyde in Textile Auxiliaries by Gas Chromatography-Mass Spectrometry

Yang LU,Kai WANG,Jian-ying JIANG
DOI: https://doi.org/10.3969/j.issn.1001-7003.2008.06.009
2008-01-01
Advanced Materials Research
Abstract:Formaldehyde in some textile auxiliaries was determined by gas chromatography-mass spectrometry(GC-MS). The formaldehyde reacted with 2,4-dinitrophenyldrazine/hydrochloric acid solution to form hydrazone,then extracted by methylene chloride.Quantitative determinations were performed by GC-MS.A good linear range of 20-500mg/kg was obtained with a regression coefficient of 0.999,the recovery was in the range of 91.4%-100.2%,and the limit of determination was 10mg/kg.The method was simple,sensitive,and it could avoid the disturbance of impurity in textile auxiliaries.