Content determination of methionine in Methionine and Vitamin B 1 for injection by HPLC

Hui XU,Biao MA,Yi LU
DOI: https://doi.org/10.3969/j.issn.1006-0103.2006.02.043
2006-01-01
Abstract:OBJECTIVE To establish a method for determining methionine in Methionine and Vitamin B_1 for injection.METHODS HPLC method was used and the seperation was performed on a column packed with amino chemically bonded silica(250 mm×4.6 mm,5 μm).The mobile phase was acetonitrile-25 mmol·L~(-1) phosphate buffer solution(60∶40,adjusting pH3.5)with flow rate of 0.8 ml·min~(-1).The detective wavelength was set at 210 nm.RESULTS The linear range was good in 0.128~0.300 mg·ml~(-1)(r=0.9999).The average recovery was 100.19% with RSD of 0.70%(n=9).CONCLUSION The method is simple,sensitive and accurate with a high reproducibility.
What problem does this paper attempt to address?