Analysis & Prevention on Pull-in Failure of Force Feedback Micro-Accelerometer after Heavy Impact

WAN Cai-xin,DONG Jing-xin,LIU Yun-feng
DOI: https://doi.org/10.3969/j.issn.1005-6734.2007.05.025
2007-01-01
Abstract:An impact load causes the proof mass of a micro accelerometer greatly depart from the balance position,making the nonlinear effect of the differential electrostatic force generator show out.The consequence is that the negative feedback model is nolonger suitable,resulting in the failure of micro accelerometer.To improve its reliability,the paper analyzes the control characteristic of MEMS sensor in closed loop control system with the feedback electrostatic forces in various restrictions,and proposes an anti-pull-in criterion which shows how to determine the system parameters of micro accelerometers with known mechanical parameters of the stopper.The experiments verifie that the micro-accelerometers,designed by the anti-pull-in criterion,never suffer pull-in failure even the impact far exceeds the accelerometer’s maximum measurement range.