THE EFFECT OF EDTA ON THE DEGRADATION OF 4-NITROPHENOL IN MICRO-ELECTROLYSIS SYSTEM

Song LI,Bo LIU,Qi WANG,Dong-dong YAN,Wen-fei WU,Ze-zhi CHEN
DOI: https://doi.org/10.3321/j.issn:0254-6108.2009.06.001
IF: 4.236
2009-01-01
Environmental Chemistry
Abstract:The main disadvantage of conventional micro-electrolysis treatment is that the degradation efficiency is not very high.To solve this problem,the effect of EDTA enhancement on the degradation of 4-NP in the micro-electrolysis/EDTA system was investigated,during which EDTA and 4-NP was degraded by the micro-electrolysis system.The results showed that EDTA could improve the removal rate of 4-NP.The operating conditions for degradation of 4-NP(1000 mg·l-1) in the micro-electrolysis/EDTA system were optimized by individual factor experiments and they were as following:C(Fe)=120 g·l-1,C(C)=20 g·l-1,C(EDTA)=1 mmol·l-1,pH=3.Under this condition,4-NP removal rates reached 89.7% within 60 min,while the removal rate of 4-NP was only achieved 53.8% by the convention micro-electrolysis treatment.The most deserves attention was that micro-electrolysis/EDTA system also displayed a reasonable good degradation activity in a neutral condition.The removal of 4-NP in micro-electrolysis/EDTA system was over 63.5% at pH of 7,while it was only 19.5% in micro-electrolysis system.The degradation products of 4-NP were identified with GC/MS methods and the degradation pathways of 4-NP were discussed.
What problem does this paper attempt to address?