Experimental Modeling Study of Deep Buried Metro Station Fires(1)-Experimental Design

ZHONG Mao-hua,SHI Cong-ling,TU Xu-wei,FU Tai-ran,HE Li,LI Pei-de
DOI: https://doi.org/10.3969/j.issn.1673-193x.2006.01.001
2006-01-01
Abstract:With the development of inter city rail transit in China, more and more stations deep buried metro station will be built. The fire safety in these metro stations should be inspected much more and studied further. In this and the fol lowing papers, fire experimental studying in deep-burying island model metro station will be introduced. This paper mainly present the design of model experiment, big systems of public area in station, TVF, TEF, ventilation system of tunnels and measurement system.
What problem does this paper attempt to address?