Strength Analysis on High Speed Shaft Coupling

SHENG Xuanyu,WANG Liankui
DOI: https://doi.org/10.3321/j.issn:1000-7857.2007.23.009
2007-01-01
Abstract:Shaft coupling is used in the power conversion unit of High Temperature Gas-cooled Reactor Gas Turbine (HTR-GT) system to connect the helium turbine and gear box. A three dimensional assemble model is built in the design software CATIA. The stresses in shaft coupling are calculated by ABAQUS for CATIA. The maximum Von Mises stress caused by centrifugal force is 303 MPa, that caused by bolt pre-tightening force is 167 MPa and that caused by moment of torque is 1 MPa. The first two maximum stresses occur at the bolt hole near the maximum outer diameter, so the total stress would be 470 MPa.
What problem does this paper attempt to address?