Numerical Simulation Research of Distribution of Fire Smoke Within Manned Spacecraft's Cabin

胡海兵,王彦,王锋,方俊,王进军,张永明
DOI: https://doi.org/10.3969/j.issn.1674-5825.2012.01.010
2012-01-01
MANNED SPACEFLIGHT
Abstract:Based on the structure of the international space station's actual cabin, a similar experimental model was established to conduct the numerical simulation research of the distribution of fire smoke in sealed cabin with foreced ventilation in mierogravity environment. There is forced ventilation of 45° diagonal inlet airflow from the top and bottom outlet of natural ventilation. FLUENT software is used for numerical simulation of the indoor airflow to check whether the thermal comfortableness requirements of the astronauts can be met. At the same time, fire is introduced to study the distribution of fire smoke concentration in the sealed cabin and with forced ventilation in microgravity environment . The fire is set both in the center of floor and the wall, and Large Eddy Simulation (LES) method is used to solve the Navier-Stokes equations. The simulation results could provide theoretical guidance for reasonable installation of photoelectric smoke detectors in spacecraft's cabin.
What problem does this paper attempt to address?