The MCNP simulation of the X-ray leakage of X-ray security inspection Equipment

WANG Kai,LIU Bin,HU Wen-chao,ZHAO Wei
DOI: https://doi.org/10.13491/j.cnki.issn.1004-714x.2011.04.039
2011-01-01
Abstract:Objective To simulate the radiation leakage of the X-ray security inspection equipment used in the subways stations.Methods We use the MCNP4C code to simulate the X-ray leakage of the equipment during the working process.Result the biggest amount of radiation received by the body is 8.26μSv/a,however,if the Lead screens of the X-ray security equipment is intact,the amount of radiation received by the body is only 0.0727μSv/a.The final.Conclusions When the baggage get in /out the X-ray security inspection equipment,the gas in Lead screens was made,and then the amount of radiation received by human body increased;The amount of radiation received by the body is close to but still below 10μSv/a which is the exemption criteria set by the "safety of radiation sources of ionizing radiation protection and basic standards"(GB18871-2002).
What problem does this paper attempt to address?