Muon radiography experiments on the subway overburden structure detection

Xin Mao,Zhiwei Li,Shuning Dong,Jingtai Li,Jianming Zhang,Jie Pang,Yaping Cheng,Bin Liao,Xiaoping Ouyang,Ran Han
DOI: https://doi.org/10.1016/j.nima.2023.168391
2023-03-17
Abstract:Muon radiography is an innovative and non-destructive technique for internal density structure imaging, based on measuring the attenuation of cosmic-ray muons after they penetrate the target. Due to the strong penetration ability of muons, the detection range of muon radiography can reach the order of hundreds of meters or even kilometers. Using a portable muon detector composed of plastic scintillators and silicon photomultipliers, we performed a short-duration(1h) flux scanning experiment of the overburden above the platform and tunnel of the Xiaoying West Road subway station under construction. With the observation direction facing up, the detector is placed on the north side of the track and moved eastward from the platform section inside the station to the tunnel section. The scanning length is 264m and a total of 21 locations are observed. By comparing the observed and predicted values of the muon survival ratio at different locations, the experiment accurately detects the jump in thickness at the interface of the platform section and tunnel section. Furthermore, unknown anomalies caused by random placed light brick piles and side passage mouth above the observation locations are detected and confirmed later. This experiment verifies the feasibility of using natural muons to quickly detect abnormal structures of the overburden of tunnel, and shows that muon radiography has broad application prospects in tunnel safety and other similar aspects.
Instrumentation and Detectors,Applied Physics
What problem does this paper attempt to address?
The paper attempts to address the problem of how to use naturally occurring muons (secondary particles of cosmic rays) for non-invasive, high-precision internal density structure imaging in the detection of structural anomalies in the overburden above urban subway tunnels. Specifically, the researchers conducted muon flux scanning experiments inside subway tunnels to verify the feasibility of muography in the rapid detection of anomalous structures in the overburden above tunnels and demonstrated its broad prospects in similar applications such as tunnel safety. The background of the paper points out that the rapid development of subway construction in China brings with it safety issues in tunnel construction and operation that cannot be ignored. The compactness and stability of the soil layer above the tunnel directly affect the safety of the subway. Traditional geophysical methods such as electromagnetic, seismic, and gravity methods each have their advantages and disadvantages, while muography has the advantages of high precision, deep detection depth, and non-destructiveness, making it particularly suitable for detecting the internal structure of large targets like urban subway tunnels, which are not suitable for invasive and destructive methods. The researchers conducted muon flux scanning experiments at the Xiaoying West Road subway station in Beijing, analyzing anomalies in the overburden and deriving the average density distribution and average thickness distribution. The experimental results showed that muography could accurately detect the density loss anomaly caused by the first-floor hall of the subway station, as well as unknown anomalies caused by randomly stacked lightweight brick piles and side passage entrances. This demonstrates the potential of muography in engineering applications.