Security Evaluation of the Nuclear Instrument Measuring Earth Density and Humidity Used in Chinese Railroad Construction Company(CRCC)

Wei Yang
2000-01-01
Abstract:The evaluation was based on 13 imported nuclear instruments being used in the construction of expressway.It was showed that the shell of the instrument had a radiation level of 138.11 μSv·h -1 and at the 10 cm distance the level was 40.29 μSv·h -1 .No material pollution was detected.The operation to turn on or turn off the instrument led to a short raise radiation level within 1 m diameter.However,the radiation declined rapidly with the distance far away from it .The level approached the natural baseline at the spot of 5 m away.An operator would endure 0.20 μSv equivalent dosage in one complete operation.It was theoretically suggest that an operator should not operate the instrument more than 70 times in a day.Whereas the current frequency is 76.5 times per day in an average.Those who carried on the instrument would endure an equivalent dosage of 2.05 mSv per year.The operator also endured much unexpected radiation because of the careless management and the lack of consciousness of protection.For example,some instruments were stored under the operator's bed.This could make the endured equivalent dosage become as high as 155.05 mSv per year.