The radiation doses monitoring and protection of RDS111 cyclotron

LIU Ping,GUAN Yi-hui,ZHAO Jun,刘平,管一晖,赵军,许震生,薛方平,张政伟
2006-01-01
Abstract:Objective To monitor the radiation dose produced by RDS111 cyclotron and to study the relationship between dose and target current for the radiation protection of the medical staff and the pub- lic.Methods Radiation dose rate of the γ ray and neutron inside and outside of the cyclotron room was measured using radiation dose meter during the production of ~(11)C,~(13)N,~(15)0 and ~(18)F with RDS111 cyclotron by target current 40 μA.The radiation dose rate was also measured in different target current.Also the annual dose was calculated.Results The radiation dose rate of all measuring points in the cyclotron room was less than 15 μSv/h except one,whereas outside the room,all the measuring points was less than 0.5 μSv/h. The annual dose of occupational people was not greater than 1.04 mSv.There was a linear fit between the radiation dose rate and the target current.Conclusion Under normal operation,the annual radiation dose received by occupational people and general public does not exceed the safety standard of our country(20 mSv for occupational people and 5 mSv for general public).