Study on CYCIAE-100 Radiation Field and Residual Radioactivity

Bi Yuan-Jie,Zhang Tian-Jue,Jia Xian-Lu,Zhou Zheng-He,Wang Feng,Wei Su-Min,Zhong Jun-Qing,Tang Chuan-Xiang
DOI: https://doi.org/10.1088/1674-1137/33/s2/012
2009-01-01
Abstract:The accelerators should be properly designed to make the radiation field produced by beam loss satisfy the dose limits. The radiation field for high intensity H- cyclotron includes prompt radiation and residual radiation field. The induced radioactivity in accelerator components is the dominant source of occupational radiation exposure if the accelerator is well shielded. The source of radiation is the beam loss when cyclotron is operating. In this paper, the radiation field for CYCIAE-100 is calculated using Monte Carlo method and the radioactive contamination near stripping foil is studied. A method to reduce the dose equivalent rate of maintenance staff is also given.
What problem does this paper attempt to address?