Scanning electron microscopic observations of human dentine after cavity preparation by ultrasonic device

LIU Bin,NI Bing,CHEN Wei-min,LIANG Jing-ping
DOI: https://doi.org/10.15956/j.cnki.chin.j.conserv.dent.2010.08.010
2010-01-01
Abstract:AIM:To analyze the different surface characteristics of the dentine floor by an ultrasonic cavity preparation,in comparison to the preparation by a high-speed handpiece with diamond burs.METHODS:Sixty human premolars with or without buccal or lingual cervical caries were divided randomly into two groups(each group has 4 caries surfaces and 12 non-caries surfaces).Cavities were prepared on the buccal and the lingual surfaces of each tooth using ultrasonic device or high-speed handpiece respectively.After the preparation,the samples were analysed using electron scanning electron microscopy to ascertain the surface characteristics of the dentine at the cavity floor.RESULTS:An inhomogeneous smear layer was produced on the surface of the cavity dentin floor by the preparation with ultrasonic device.The position of some tubular openings could be detected.There was a firmly and well-defined smear layer on the dentin surface prepared by the high-speed handpiece.The dentine tubule orifices were plugged with material.CONCLUSION:Smear layer can be detected on the dentin surface prepared by both ultrasonic device and high-speed handpiece with the difference in the form and characteristics of the smear layer,and might have adverse effect on the adhesion of composite resin.