Finite element analysis of endodontically treated teeth restored with two different post systems

Jianguo TAN,Min FENG,Lijing ZHOU
DOI: https://doi.org/10.3969/j.issn.1003-7632.2006.02.025
2006-01-01
Abstract:Objective To determine the stress distribution of endodontically treated teeth restored by two post with different moduli of elasticity. Methods Two-dimensional finite element method was utilized to analyze the stress distribution within the post-tooth complex and to compare two post systems between glass fiber reinforced composite post and cast Ni-Cr alloy post. Results Stress distribution patterns of endodontically treated teeth were obviously different between the two post systems of different materials.Glass fiber reinforced composite post induced a stress distribution that was similar to that of natural tooth and generally with a lower stress level. While Ni-Cr post alters stress distribution of natural tooth and critical stress concentration occurs at the post-dentin interface. Conclusion Restoring the endodontically treated teeth by the post with low moduli of elasticity similar to sound dentin could reduce the risk of root fracture.
What problem does this paper attempt to address?