Electrolyte accelerated corrosion technique for reinforced in concrete

FANG Cong-qi,QIAN Zhi-wei,WANG Zhuo-yi,YUAN Yu-fei,CHEN Xin-yu
DOI: https://doi.org/10.3969/j.issn.1002-3550.2007.02.005
2007-01-01
Abstract:Electrolyte corrosion technique is often used to induce steel corrosion in concrete for acceleration of the process.The objective of this paper is to investigate effectiveness and error range of electrolyte corrosion technique applied to acceleration of steel corrosion in concrete.Test results from smooth reinforcing steel bars cast into concrete of different dimensions showed that the measured corrosion levels agreed with those theoretically calculated based on Faraday's Law.Electric resistance was measured during the corroding.Electric resistance was demonstrated changing with the cumulative corrosion level.At the beginning of the corrosion electric resistance increased rapidly to its maximum value,but decreased drastically thereafter until it decreased slowly and tended to stop changing around its minimum value.Comparisons of the current results with those from the previous study indicated that both smooth bar and deformed bar showed a similar electrical resistance-corrosion relationship.
What problem does this paper attempt to address?