Applicability of Accelerated Corrosion Method of Steel Bars in Cracked Concrete Structure

王雪松,金贤玉,田野,李蓓,金南国
DOI: https://doi.org/10.3785/j.issn.1008-973x.2013.04.001
2013-01-01
Abstract:Four electrifying corrosion methods were applied to simulate the corrosion process of reinforcement in concrete under loads.The surface characteristics of corroded reinforcement were analyzed together with the microstructure and element composition of corrosion products.Experimental results demonstrate that very little excessive rust can be found from the reinforcement in the concrete beam corroded with the embedded auxiliary electrode method,and the expansion force generates very fast which leading to a rapid development of the corrosion cracks.The corrosion rate of reinforcement corroded with half soaking method ranks second,but the excessive rust generates on the surface of corroded reinforcement may affect the oxygen diffusion in concrete,and thereby influence the corrosion process.The expansion force generates very slowly in the reinforced concrete beam corroded with the surface coating method.As the corrosion products of the reinforcement corroded with soaking method are continuously taken away by water,the expansion force develops the most slowly,the electrifying lasts for the longest time,and the crack width can't reach the anticipated value as the corrosion crack expands the most slowly.The theoretical corrosion mass in each accelerated corrosion method is higher than the experimental corrosion mass.
What problem does this paper attempt to address?