Analysis on Transient Performance of Mixed Flow Pump During Stopping Period

CHEN Wei,KE Xian-wen,WU Da-zhuan,WANG Le-qin
DOI: https://doi.org/10.3969/j.issn.1005-0329.2006.12.001
2006-01-01
Abstract:To investigate the transient hydrodynamic performance of mixed flow pump at different rotational speeds during the stopping period,some theoretical and experimental studies are carried out,and the analysis of the test results are presented.The experiment equipments and test methods for testing the transient hydrodynamic performance are introduced.The transient hydrodynamic performances at different rotational speeds are tested.The thrice polynomial curve equation is used to simulate the real tested-curve.The test results indicated that the flow-rate and the pump head decreased rapidly at the very beginning of the stopping,and also the pipe energy,but there were no noises and air bubble produced during this period,than some operation notices are presented.The test results also indicated that the prediction results can fit the real tested-curve on the whole.The test and numerical results built the foundation for academic design and practical use on the pump transient hydrodynamic performance aspect.
What problem does this paper attempt to address?