Experimental Study on Hydrodynamic Performance of A Cavitating Centrifugal Pump During Transient Operation

Dazhuan Wu,Leqin Wang,Zongrui Hao,Zhifeng Li,Zhiren Bao
DOI: https://doi.org/10.1007/s12206-009-1217-3
IF: 1.81
2010-01-01
Journal of Mechanical Science and Technology
Abstract:An experimental study has been carried out in order to analyze the cavitation of a centrifugal pump and its effect on transient hydrodynamic performance during transient operation. The transient characteristics of the centrifugal pump were tested under various suction pressure and starting conditions. In transient operation of continuous starting and stopping process, instantaneous rotational speed, head, flow rate and suction pressure of the pump were measured. The effect of cavitation on transient performance of the centrifugal pump during transient operation was analyzed, and then the effects of starting acceleration rate and suction pressure of pump on cavitation were presented. Results showed that the cavitation would be delayed during rapid starting period. However, in the condition of low suction pressure and high rotational speed, pump cavitation is inescapable even if the starting period is less than a second. After the serious transient cavitation occurred, the transient performance of centrifugal pump would decline obviously, and the instantaneous head of pump would fluctuate.
What problem does this paper attempt to address?