Measurement of Sound Transmission Loss in an Acoustic Pipe Using Pulse Method

Sun Liang,Hou Hong,LiYing Dong,Ren Weiwei
2010-01-01
Abstract:The sound transmission loss measurement is usually executed by multi-microphone method in an impedance tube.A single broadband frequency Butterworth sound pulse is generated in an acoustic pipe by measuring the system transfer function and using inverse filter principle which can eliminate reflections from pipe exit and complement the frequency response of loudspeaker at low and high frequencies.The sound transmission loss of a kind of material is measured using the butterworth pulse as incident wave.Through comparison with the SW466 impedance tube results,it is found that the results obtained from the proposed method agree well with those from the standard method in frequency range from 500 to 4500Hz.Since only single microphone is needed and measurement repeatability is good,the proposed method is believable as an effective method for transmission loss measurement.
What problem does this paper attempt to address?