Measurement of Leak Location in Buried Iron Water Pipe with Acoustic Emission and EMD

GU Xiao-hong,HOU Di-bo,ZHOU Ze-kui
DOI: https://doi.org/10.3785/j.issn.1008-973x.2006.07.001
2006-01-01
Abstract:A method based on empirical mode decomposition(EMD) and power feature extraction to locate the leak point was presented to overcome the disadvantage of location precision being low(affected by the noising and the propagation modes of sound) of direct cross-correlation method to pinpoint the leak point.This method based on data sampled by acoustic emission sensors,analyzed the direct cross-correlation affected by the noising and the propagation modes of sound,and decomposed the signal into a series of frequency bands,from which a few useful frequency bands were selected by power feature extraction,and then the leak point was determined by comparing the correlation coefficient.Simulation and experiments indicated that the method presented above eliminated the disadvantages of direct cross-correlation and improved the precision of location.
What problem does this paper attempt to address?