Analysis and Experimental Study on the Measurement of Pipe Wall Thinning by Perturbation Method

Jian MA,Ying-li ZHOU,Yang ZHAO,Qi-wu WANG,Yang JU
DOI: https://doi.org/10.14183/j.cnki.1005-6122.201706016
2017-01-01
Abstract:The inside of the metal pipe,which is short circuited at both ends,is regarded as a resonant cavity,and the thinning of the pipe wall leads to a change in the volume of the cavity.Thus,the deviation of the resonant frequency can be used to evaluate the wall thickness.Based on the theory of resonant cavity perturbation,the measurement system of pipe wall thinning is constructed,and a single coaxial cable is used to transmit and receive TM01 mode inside the pipeline to realize the detection of pipe wall thinning.The finite element model of the detection system is established,and then the parameterized sweep calculation of the degree of thinning is carried out.Correspondingly,the swept measurement system is built,and resonant frequencies versus different thicknesses are obtained.Through the comparison with the finite element calculation results,the measured data has high degree coincidence with it.And the offset of the resonant frequency increases with the thickness of the pipe wall.Therefore,the resonant cavity perturbation method can be used for the assessment of pipe wall thinning,which is an effective non-destructive testing method for in-service pipelines.
What problem does this paper attempt to address?