Ultrapure Water Production by Electrodeionization(EDI)—Comparison of Two Models with Different Inner Flow Path

Zhao Jian,Wang Jianyou,Wu Zhiqiang,Bian Yanfang,Su Yulong
DOI: https://doi.org/10.3969/j.issn.0465-7942.2010.04.010
2010-01-01
Abstract:Taking Ca~(2+)、Mg~(2+) added RO water as feed water,a specific inner flow path was adopted in EDI process for ultrapure water production,according to which the dilute stream had two flow passages while the concentrate stream just had one.In order to achieve goals of water quality improving and hardness precipitation preventing simultaneously,the flow direction of concentrate stream was changed to constitute a countercurrent in first and second flow passage of dilute stream respectively.It was proved that the model in which the first passage of dilute stream was countercurrent with concentrate stream performed better in hardness removal, energy consumption and scale averting than the other.With feed hardness of 11.7 mg/ L(as CaCO_3),the improved EDI process could give a total salt rejection of 99.8%.The hardness rejection was near 100%while the energy consumption was 0.26 kW·h/m~3.In durative experiment of 85 h,the steady product resistivity was between 17.4 and 17.8 MΩ·cm.No precipitation was found.