Rreason analysis on deviation of online flue gas NOx concentration measurement

SONG Xiaohong,YAN Weiming,TAO Zhiguo,ZHANG Yang,WEN Liang
DOI: https://doi.org/10.3969/j.issn.1002-3364.2013.02.086
2013-01-01
Abstract:Deviation exited between the four CEMS's measurement for NOx concentration in flue gas denitrification and desulfurization systems in a power plant,analysis showed that the reason was that due to the low NOx concentration in flue gas,the online instruments had large instrument error when measuring NOx with too low concentration.Moreover,NOx at the outlet of the denitrification system was not evenly distributed,causing the test points of the online instruments have no representativeness,which was another important reason.Thus,some suggestions were given,such as reasonably arranging the baffle,adjusting the ammonia injection grid,installing flue gas disturbance device and calibrating the analyzer with standard gas having concentration that is close to the actual gas's.