Transmission Characteristics of Coupled Pipe System in Thermoacoustic Engine

BAI Kun,QIU Li-min,WANG Bo,SUN Da-ming,CHAO Wei
DOI: https://doi.org/10.3785/j.issn.1008-973x.2009.08.021
2009-01-01
Abstract:For optimizing the match between thermoacoustic engine and pulse tube refrigerator,the transmission equation of a coupled three-pipe system was derived based on the fluid network model and the linear thermoacoustic theory.The amplification characteristics of pressure ratio and the acoustic power needed at the inlet of the coupled pipe system with different pipe diameter and length were calculated and compared based on DeltaE.With suitable pipe diameter,experiments were done on a travelling-wave thermoacoustic engine to verify the amplification characteristics of pressure ratio of the coupled pipe system.RC load method was used to measure the acoustic power at the end of the coupled system,and the characteristics of the output acoustic power changing with the impedance at the end of the coupled system were studied.Tendency agreement between the calculation prediction and experimental results was obtained.Using nitrogen as working fluid at 2.20 MPa,the pressure ratio of 1.50 was obtained at the end of the coupled system,and the maximum output acoustic power obtained under certain resistance was 105 W.