Abstract:Numeric temperature field models for external walls with thermal insulation layers were developed based on the finite differential method,in which solar radiation and environmental temperature were taken into account.By applying the model,the temperature field of an externally or internally insulated wall in typical seasons in Beijing was calculated and analyzed.In the calculation,the different effects of either inner or outer thermal insulation layers were taken into account.The calculations showed that the influence of solar radiation on the temperature field of external walls was significant and the degree of influence depended on wall positions and seasons.The structural layer's temperature range increased significantly when there was inner thermal insulation,compared to the range of an externally insulated wall.The temperature of the structural layer in an externally insulated wall remained above 0℃,while internally insulated walls sometimes went below 0℃,undergoing positive and negative cycling.The temperature of the outer protection layer of the externally insulated wall obviously changed in the four seasons,with an annual highest temperature of 67℃.