Application of lumbar interbody fusion with the tantalum cage in the recurrent lumbar disc herniation after decompression

HE Rui,ZHANG Wen-zhi,SHANG Xi-fu
DOI: https://doi.org/10.3969/J.issn.1005-7234.2013.05.008
2013-01-01
Abstract:Objective To assess the treatment effect and feasibility of lumbar interbody fusion with titanium cage for recurrent lumbar disc herniation.Methods Twenty-two patients(8 males,14 females;average 62.3 years old,ranged from 34 to 67) with recurrent lumbar disc herniation after decompression were recruited from September 2009 to April 2010.All patients were treated with transforaminal posterior lumbar interbody fusion(TLIF),and domestic nail-stick systems were applied in 14 patients,imported in 8 patients.Intervertebral bone grafting was the resection part of the vertebral lamina and articular process.All patients were observed every month by X-ray and partially by CT.The outcomes were evaluated by intervertebral bony fusion and location of internal fixation and cage.Results Each operation was successfully completed,and the postoperative symptoms were significantly improved.There was no cage subsidence and broken nail-stick in the patients,and all patients got bony fusion of the fixation segments within 4.6 months.One patient with cage broken showed no postoperative discomfort,and X-ray showed bony fusion and no cage displacement 4 months after operation.Conclusion The lumbar interbody fusion with the tantalum cage in the treatment of recurrent lumbar disc herniation after decompression especially for total laminectomy has the advantage of less bone grafts,quicker bony fusion,and less complications.