Causes for the Formation of Cr6+in Cr3+ Passivation Film and the Affecting Factors

LIU Guo-qin,LI Jin-hua,ZHOU Bao-xue
DOI: https://doi.org/10.3969/j.issn.1000-4742.2008.03.009
2008-01-01
Abstract:Trace hexavalent chromium will appear in the trivalent chromium passivation film of zinc coating after a period of time in the air.The effects of various parameters(passivation solution temperature,pH value,passivation time,concentration,and ingredients,etc.) on the formation of hexavalent chromium in trivalent chromium passivation film for zinc coating and the causes for the formation are discussed.