Development of a Four-Post Frame Integral Loading/rotating Device

LI Da-ying,HU Xiao-fang,XIA Yuan-ming
DOI: https://doi.org/10.3969/j.issn.0253-2778.2006.04.012
2006-01-01
Abstract:An integral loading/rotating device for real-time synchrotron radiation CT system for materials analysis is introduced.With this device,rigid rotation of the specimen was realized by synchronous rotation of the upper and low grips,and the specimen was loaded(tension/compression) by the axial movement of the upper grip.The device adopted a five-dummy-plate four-post framework and the five dummy plates' center through holes formed the center datum of the framework;moreover,the device adopted many other techniques,such as excessive position fix,straight-line rolling bearing,high delicate ball screw,high centring grip holder and high-precision synchronously closed-loop control and so on.All the techniques mentioned above assured the high accuracy in geometry motion and positioning of the device.Measurement of the device indicates that the actual accuracy is better than that of the original design.The compression test and real-time CT analysis on the foam aluminium with the real-time synchrotron radiation CT system for material analysis constructed based on this device was conducted,which proved the reliability of the device.
What problem does this paper attempt to address?