HEPS pre-collimation unit BQ magnet precision high stability pad lock position adjustment device design

Bo LIU,Lingling MEN,Hongbing XIN,Lan DONG,Bo LI,Xiaolong WANG,Tao LUO,Jing LIANG,Tong WANG,Na MA,Zhenqiang HE,Zhiyong KE,Xiaohui ZHANG,Jianxin SHEN
DOI: https://doi.org/10.11889/j.0253-3219.2019.hjs.42.110203
2019-01-01
Nuclear Techniques
Abstract:[Background] The device design requirements come from high-energy synchrotron radiation sources. [Purpose] The purpose of this study was to design a new type of magnet support adjustment device that can meet the locking stability accuracy of 5 μm and the adjustment accuracy of 2 μm. [Methods] According to the actual working conditions, the modal was statically and modally analyzed in ABAQUS software. Use inventor to design support and adjustment devices that meet the accuracy requirements, including high-precision adjustment plates, high-precision ball and high-precision gaskets.[Results] The results show that the deformation of the Ⅴ-frame and the adjustment plate is far less than the design requirements in statics, which can meet the adjustment requirements after installation, and the first-order natural frequency of the new device can meet the requirements of no resonance under the influence of ground pulsation. [Conclusions] The design idea and analysis results of the device satisfy the requirements of height, precision and rigidity at the beginning of the design, and lay a solid foundation for the subsequent beam center calibration and measurement.
What problem does this paper attempt to address?