Development of AC Parameters Measurement System for Nonlinear Resistance

SUN Wei,YAO Xueling,CHEN Jing-liang,XU Chuan-xiang
DOI: https://doi.org/10.3969/j.issn.1001-1609.2006.04.006
2006-01-01
Abstract:AC parameters measuring system of nonlinear resistances,which can adjust AC power source automatically,is developed,based on function generator MAX038,general multiplication AD734,data collecting card and computer with A/D and D/A port.The system can be used to measure AC parameters of nonlinear resistances,i.e.U1 mA,U100 μA,U10 μA and Io(total leak current),Ir(resistive current).The AC voltage output range from 0 V to 15 kV,and the harmonic value is less than 1.5%.Adopting the harmonic compensative technique,Ir can be measured,and compared with Heithley191 of high accuracy(0.1%),the measuring deviation is less than 1%.Therefore,this measuring system has higher efficiency and precision.
What problem does this paper attempt to address?