Analysis of CM Volt-Second Influence on CM Inductor Saturation and Design for Input EMI Filters in Three-Phase DC-Fed Motor Drive Systems

Fang Luo,Shuo Wang,Fei (Fred) Wang,Dushan Boroyevich,Nicolas Gazel,Yong Kang,Andrew Carson Baisden
DOI: https://doi.org/10.1109/tpel.2010.2043541
IF: 5.967
2010-01-01
IEEE Transactions on Power Electronics
Abstract:Common-mode (CM) choke saturation is a practical problem in CM filter applications. It is generally believed that the leakage inductance of CM chokes makes the core saturated. This paper analyzes two new mechanisms for CM choke saturation due to CM voltage, and these mechanisms are verified in experiment. CM choke saturation is particularly important for motor drive systems, which have a high CM voltage and comparably higher stray grounding capacitance. A model is established to describe the relationship between the CM voltage and the volume of the CM magnetic components. According to the analysis, line impedance stabilization networks (LISNs) play an important role in the design of CM magnetic components.
What problem does this paper attempt to address?